Configuring the Internal Baseband Source
R&S
®
SMBV100B
231
User Manual 1178.4460.02 ─ 03
"Peak"
The individual carriers are leveled based on their peak power and the
configured "Carrier Gain".
Example:
A multi carrier signal is composed from two waveform files.
First carrier "Gain" = 0 dB
Second carrier "Gain" = -3 dB
In the resulting multi carrier signal, the
peak power
of the second car-
rier signal will be 3 dB lower than the peak power of the first carrier
signal.
Example: Multi carrier signal composed of waveforms with dif-
ferent crest factor
A multi carrier signal is composed from two waveform files with the
following characteristics:
3GPP FDD signals with the same "Sample Rate" but
different "Crest
Factors"
.
"Peak" = 0 dBFS
"Carrier Gain" = 0 dB
The Peak values of the carrier signals are equal, the RMS values are
different.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:POWer:REFerence
Output Settings
The output settings indicate the name, the file size, and the clock rate of the currently
calculated multi-carrier output file.
Generating Multi-Carrier Signals