![Rohde & Schwarz SMBV100B User Manual Download Page 526](http://html.mh-extra.com/html/rohde-and-schwarz/smbv100b/smbv100b_user-manual_1477881526.webp)
General Instrument Functions
R&S
®
SMBV100B
524
User Manual 1178.4460.02 ─ 03
Threshold User1-2 Input
Sets the high/low threshold in volts for the signal at the User1-2 connectors.
The input signal is defined with the parameter
. The same threshold applies for
both connectors and any input signal.
Remote command:
[:SOURce]:INPut:USER:TRIGger:LEVel
[:SOURce]:INPut:USER:CLOCk:LEVel
Threshold User3-5 Input/Threshold Pulse Input
Sets the high/low threshold in volts for the signal at the User3-5 connectors.
The input signal is defined with the parameter
. The same threshold applies for
all 3 connectors and any input signal (e.g. external pulse modulation or trigger signal).
Remote command:
[:SOURce]:INPut:USER:PULM:LEVel
Impedance Clock/Trigger Input
Selects the input impedance for the external trigger/clock inputs.
Set the value to 1 k
Ω
/GND for high clock rates.
Remote command:
[:SOURce]:INPut:USER:TRIGger:IMPedance
[:SOURce]:INPut:USER:CLOCk:IMPedance
Clock Input Slope
Sets the polarity of the active slope of an externally applied clock signal.
Remote command:
[:SOURce]:INPut:USER:CLOCk:SLOPe
Trigger Input Slope
Sets the polarity of the active slope of an applied instrument trigger.
Remote command:
[:SOURce]:INPut:USER:TRIGger:SLOPe
10.2.6
How to Enable Signals and Perform Signal to Connector Mapping
This section introduces the general principle of connector configuration.
General Workflow
shows the main configuration stages, together with the corresponding
user interface dialogs.
Configuring the Global Connectors