Remote Control Commands
R&S
®
SMBV100B
726
User Manual 1178.4460.02 ─ 03
[:SOURce<hw>]:BB:DM:TRIGger:SLENgth
<SLength>
Defines the length of the signal sequence to be output in the
SINGle
trigger mode.
Parameters:
<SLength>
integer
Range:
1 to 4294967295
*RST:
1000
Default unit: symbol
Example:
See
Example "Adjusting clock, marker and trigger settings"
Manual operation:
See
[:SOURce<hw>]:BB:DM:TRIGger:RMODe?
Queries the status of signal generation.
Return values:
<RMode>
STOP | RUN
Example:
SOURce1:BB:DM:TRIGger:SOURce ELTRigger
SOURce1:BB:DM:TRIGger:SEQuence ARETrigger
SOURce1:BB:DM:TRIGger:RMODe?
Response: RUN
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:BB:DM:TRIGger:EXTernal:SYNChronize:OUTPut
<Output>
Enables signal output synchronous to the trigger event.
Parameters:
<Output>
0 | 1 | OFF | ON
*RST:
1
Example:
See
Example "Adjusting clock, marker and trigger settings"
Manual operation:
See
"Sync. Output to External Trigger/Sync. Output to Trigger"
[:SOURce<hw>]:BB:DM:TRIGger:ARM:EXECute
Stops signal generation; a subsequent internal or external trigger event restart signal
generation.
Example:
Example "Adjusting clock, marker and trigger settings"
Usage:
Event