![Rohde & Schwarz SMBV100B User Manual Download Page 293](http://html.mh-extra.com/html/rohde-and-schwarz/smbv100b/smbv100b_user-manual_1477881293.webp)
Configuring the RF Signal
R&S
®
SMBV100B
291
User Manual 1178.4460.02 ─ 03
The display is disabled when:
–
Chapter 6.10, "Varying the RF Signal in List or Sweep
Remote command:
[:SOURce<hw>]:FREQuency[:CW|FIXed]
Offset
Sets the frequency offset.
This value represents the frequency shift of a downstream instrument, like for example
a mixer.
The "Frequency" value displayed in the status bar is the resulting frequency, as it is at
the output of the downstream instrument. The frequency at the R&S
SMBV100B RF
output is not changed.
See
"RF frequency and level display with a downstream instrument"
Remote command:
[:SOURce<hw>]:FREQuency:OFFSet
Multiplier
Sets the multiplication factor for the RF frequency.
This value represents the multiplication factor of a downstream instrument, like for
example a multiplier.
The "Frequency" value displayed in the status bar is the resulting frequency, as it is at
the output of the downstream instrument. The frequency at the R&S
SMBV100B RF
output is not changed.
See
"RF frequency and level display with a downstream instrument"
Remote command:
[:SOURce<hw>]:FREQuency:MULTiplier
User Variation
Defines and activates a user-defined step width for varying the RF frequency or RF
level with the rotary knob.
If disabled, the step width varies in steps of one unit at the cursor position.
Variation Active ← User Variation
Activates the set user-defined step width.
Remote command:
[:SOURce<hw>]:FREQuency:STEP:MODE
Variation Step ← User Variation
Sets the user-defined step width.
Remote command:
[:SOURce<hw>]:FREQuency:STEP[:INCRement]
[:SOURce<hw>]:POWer:STEP[:INCRement]
RF Frequency Settings