You can enable this feature, when you are working with sawtooth shapes in sweep
mode "Single" or "External Single".
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Manual operation:
See
[:SOURce<hw>]:LFOutput:SWEep[:FREQuency]:RUNNing?
Queries the current status of the LF frequency sweep mode.
Return values:
<State>
0 | 1 | OFF | ON
Example:
See
Usage:
Query only
[:SOURce<hw>]:LFOutput:SWEep[:FREQuency]:SHAPe
<Shape>
Sets the cycle mode for a sweep sequence (shape).
Parameters:
<Shape>
SAWTooth | TRIangle
*RST:
SAWTooth
Example:
See
Manual operation:
See
[:SOURce<hw>]:LFOutput:SWEep[:FREQuency]:SPACing
<Spacing>
Selects linear or logarithmic sweep spacing.
Parameters:
<Spacing>
LINear | LOGarithmic
*RST:
LINear
Example:
See
Manual operation:
See
[:SOURce<hw>]:LFOutput:SWEep[:FREQuency]:STEP:LOGarithmic
<Logarithmic>
Sets the step width factor for logarithmic sweeps to calculate the frequencies of the
steps.
For information on how the value is calculated and the interdependency with other
parameters, see
Chapter 6.10.2.1, "Correlating Parameters in Sweep Mode"
SOURce Subsystem