R&S
FS-K30
General Information
Limit
Line
Software Manual 1300.6637.42 - 03
36
1.9.1.2 Limit
The
Limit
field specifies the type of result that this limit line applies to (Noise or Gain)
and the type of limit that should be applied (Upper or Lower).
1.9.1.3 Comment
The
Comment
field allows the user to attach a textual description to a limit line. The comment
can contain any combination of number, letters and characters.
1.9.1.4 Frequency / Limit Table
The
Frequency/Limit Table
lists the Limit values for different Receive Frequency (
RF)
values. R&S FS-K30 will interpolate between points in the list for
RF
values used in a
measurement that are not explicitly entered in the Frequency/Limit list.
When focus is moved to the Frequency/Limit Table at the bottom left of the view, the
current parameter in the table is highlighted. Navigation through the table is possible in
all four directions using the cursor keys.
It is possible to add individual values directly into the Frequency/Limit Table, including
insertion and deletion of
RF/Limit
value pairs (rows in the list). The list can contain up
to 100
RF/Limit
value pairs. Note that the order of
RF
values must be in ascending
sequence.
Fig. 14 Frequency/Limit table
INSERT
The
INSERT
softkey inserts a new row in the Limit Table directly above the row
currently selected. The cursor will be moved to the corresponding column in the new
row ready for detailed entry. The
INSERT
softkey shall be disabled when the maximum
number of entries in the Limit Table has been reached.
Fig. 15 Inseting limit line data