R&S
FS-K30
Remote Control
Status
reporting registers
Software Manual 1300.6637.42 - 03
132
3.2.1 Description of the Status Registers
All the status registers shown in Fig. 43 are the same as those provided by the base
system, with the exception of the following:
I
STATus:OPERation – Although this register is provided by R&S FSP Kernel main,
R&S FS-K30 makes use of bits 4 & 7 in this register which are not used within R&S
FSP Kernel main
I
STATus:QUEStionable - Although this register is provided by R&S FSP Kernel
main, R&S FS-K30 makes use of bit 11 in this register which is not used within
R&S FSP Kernel main.
I
STATus:QUESTionable:ACPLimit – This register is provided by the analyser and is
not available from the R&S FS-K30 command tree
I
STATus:QUESTionable:LIMit2 – This register is provided by the analyser and is not
available from the R&S FS-K30 command tree
I
STATus:QUESTionable:LMARgin<1|2> – These registers are provided by the
analyser and are not available from the R&S FS-K30 command tree
I
STATus:QUESTionable:POWer – This register is provided by the analyser and is
not available from the R&S FS-K30 command tree
I
STATus:QUEStionable:CORRection – This register is provided by the R&S FS-K30
option itself.
The deviations from the status register structure of the base system are detailed below.
STATus:OPERation Register
In the CONDition part, this register contains information on which actions the instrument is
being executing or, in the EVENt part, information on which actions the instrument has
executed since the last reading. It can be read using commands
"STATus:OPERation:CONDition
?" or
"STATus:OPERation[:EVENt]?
".
Bit No
Meaning
0
CALibrating
This bit is set as long as the instrument is performing a calibration.
1 to 3
These bits are not used
4
MEASuring
A ‘1’ in this bit position indicates that a measurement is in progress.
R&S FS-K30 only
5 to 6
These bits are not used
7
CORRecting
Indicates that a user calibration is in progress.
R&S FS-K30 only
8
HardCOPy in progress
This bit is set while the instrument is printing a hardcopy.
9 to 14
These bits are not used
15
This bit is always 0