97
Connecting the Kinetix 6000 Drive System
Chapter
5
Wire the Contactor Enable (CED) Connector
This example applies to any IAM, common-bus leader IAM, or common-bus
follower IAM module.
Figure 49 - IAM Module (CED connector)
Table 56 - Contactor Enable (CED) Connector
CONT EN-
CONT EN+
1 2
Kinetix 6000
IAM Module, Top View
ATTENTION:
Wiring the contactor enable relay is required. To avoid
personal injury or damage to the drive, wire the contactor enable relay
into your safety control string. Refer to Contactor Enable Relay on
.
In common-bus configurations, the contactor enable (CED) connections for
leader and follower drives must be wired in series to the safety control
string.
For interconnect diagrams, refer to Interconnect Diagram Notes beginning
on
LIM Module I/O (IOL) Connector or Other Control String
CED Pin
Signal
Recommended
Wire Size
mm
2
(AWG)
Strip Length
mm (in.)
Torque Value
N•m (lb•in)
2094-AL
xx
S, 2094-BL
xx
S, or
2094-XL75S-C
x
LIM Modules
2094-AL09 and 2094-BL02
LIM Modules
IO_COM1
IO_COM
1
CONT EN-
2.5 (14)
(1)
10 (0.38)
0.5…0.6
(4.4…5.3)
COIL_E2
COIL_A2
2
CONT EN+
(1) The actual gauge of the contactor enable wiring depends on the system configuration. Consult your machine builder, the NEC, and applicable local codes.
Summary of Contents for Allen-Bradley 2094-BC01-M01-S
Page 4: ...4 Rockwell Automation Publication 2094 UM001D EN P May 2010 Summary of Changes Notes...
Page 10: ...10 Rockwell Automation Publication 2094 UM001D EN P May 2010 Table of Contents Notes...
Page 278: ...278 Rockwell Automation Publication 2094 UM001D EN P May 2010 Index Notes...
Page 279: ......