Chapter 6
Configure and Start Up the Kinetix 6000 Drive System
Figure 78 - Node Addressing Example 3
In this example, the Kinetix 6000 (8-axis) power rail contains a double-wide
IAM module, two double-wide AM modules, one single-wide AM module, and
one slot-filler module. The slot-filler module is not assigned a SERCOS node
address, but the system identifies it with a slot location.
The leftmost slot of a double-wide module determines the node address. So, in
the example above, node addresses 02, 04, and 06 (the rightmost slots of the
double-wide modules) are not used.
SERCOS interface
TM
Tx (rear)
Rx (front)
OK
CP
08 = Slot-filler module node address
07 = AM module (axis 4) node address
06 = Not Used (AM module rightmost slot)
05 = AM module (axis 3) node address
04 = Not Used (AM module rightmost slot)
03 = AM module (axis 2) node address
02 = Not Used (IAM module rightmost slot)
01 = IAM module (axis 1) base node address
Logix Platform
(ControlLogix is shown)
SERCOS Fiber-optic Ring
1756-M
xx
SE SERCOS
interface Module
Kinetix 6000 Drive System
(8-axis power rail)
Receive
Transmit
Transmit
Receive
IMPORTANT
Slot-filler modules must be used to fill any unoccupied slot on the power
rail. However, the slot-filler modules may also be removed and replaced
by an AM or shunt module in the future.
IMPORTANT
Do not position axis modules to the right of shunt or slot-filler modules.
The added distance between non-adjacent axes can increase electrical
noise and impedance, and requires longer fiber-optic cable lengths.
Summary of Contents for Allen-Bradley 2094-BC01-M01-S
Page 4: ...4 Rockwell Automation Publication 2094 UM001D EN P May 2010 Summary of Changes Notes...
Page 10: ...10 Rockwell Automation Publication 2094 UM001D EN P May 2010 Table of Contents Notes...
Page 278: ...278 Rockwell Automation Publication 2094 UM001D EN P May 2010 Index Notes...
Page 279: ......