![Rockwell Automation Allen-Bradley 2094-BC01-M01-S User Manual Download Page 171](http://html1.mh-extra.com/html/rockwell-automation/allen-bradley-2094-bc01-m01-s/allen-bradley-2094-bc01-m01-s_user-manual_1475821171.webp)
Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
171
Troubleshooting the Kinetix 6000 Drive System
Chapter
7
PowerPhaseLossFault
(Phase Loss Flt)
E37
•
One or more phases of the input AC power is missing.
•
Axis was enabled when main (three-phase) power was removed.
•
Common-bus follower axis was enabled when DC bus power was
removed.
SHUTDOWN/ STOP
MOTION
No
SERCOSFault
(SERCOS Ring Flt)
E38
The SERCOS ring is not active after being active and operational.
STOP MOTION
No
DriveHardFault
(Self Sense Flt)
E39
Self-sensing commutation fault detected.
DISABLE DRIVE
No
DriveEnableInputFault
(Drive Enable Flt)
E43
Generated when Enable input switches off when drive is enabled.
STOP MOTION
Drive Enable Input
Yes
DriveHardFault
(Safe-Off HW Flt)
E49
Safe-off function mismatch. Drive will not allow motion. Refer to the
Kinetix Safe-off Feature Safety Reference Manual, publication
, for more information. Applies to 2094-
x
C
xx
-M
xx
-S
IAM and 2094-
x
M
xx
-S AM modules with safe-off feature.
SHUTDOWN
No
SERCOSFault
(SERCOS Same ADDR)
E50
Duplicate node address detected on SERCOS ring.
STOP MOTION
No
DriveHardFault
(Ifbk HW Fault)
E54
Current feedback hardware fault detected.
SHUTDOWN
No
DriveHardFault
(Unknown Axis)
E60
Invalid module type identified by firmware when applying power.
SHUTDOWN
No
AuxFeedbackFault
(Aux Fdbk AQB)
E61
Auxiliary encoder has encountered an illegal state transition.
DISABLE DRIVE
No
AuxFeedbackFault
(Aux Fdbk Loss)
E62
The feedback wiring is open, shorted or missing.
DISABLE DRIVE
No
AuxFeedbackNoise
(Aux Fdbk Noise)
E63
Presence of noise on auxiliary feedback cable.
DISABLE DRIVE
Feedback Noise
Yes
MotorFeedbackNoise
(Mtr Fdbk Noise)
E64
Presence of noise on motor feedback cable.
No Fault Message
(condition indicated by
on-screen message)
(Hookup Fault)
E65
Hookup procedure failed.
DISABLE DRIVE
No
No Fault Message
(condition indicated by
on-screen message)
(Atune Flt)
E66
Autotune procedure failed.
DISABLE DRIVE
No
DriveHardFault
(Task init)
E67
Operating system failed.
SHUTDOWN
No
DriveHardFault
(SCANport Comm)
E68
DPI communication failed.
STOP MOTION
No
DriveHardFault
(Objects Init)
E69
Non-volatile memory attribute out of range.
SHUTDOWN
No
DriveHardFault
(NV Mem Init)
E70
Non-volatile memory corrupted.
SHUTDOWN
No
Table 95 - Logix/Drive Fault Behavior (Continued)
Logix Fault Message
(HIM Message)
Error
Code
Description
Drive Fault
Action/Attribute
RSLogix
Programmable
Fault Action?
Summary of Contents for Allen-Bradley 2094-BC01-M01-S
Page 4: ...4 Rockwell Automation Publication 2094 UM001D EN P May 2010 Summary of Changes Notes...
Page 10: ...10 Rockwell Automation Publication 2094 UM001D EN P May 2010 Table of Contents Notes...
Page 278: ...278 Rockwell Automation Publication 2094 UM001D EN P May 2010 Index Notes...
Page 279: ......