![Rockwell Automation Allen-Bradley 2094-BC01-M01-S User Manual Download Page 216](http://html1.mh-extra.com/html/rockwell-automation/allen-bradley-2094-bc01-m01-s/allen-bradley-2094-bc01-m01-s_user-manual_1475821216.webp)
216
Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
Appendix B
Interconnect Diagrams
Figure 101 - AM Module with RDD-Series Direct Drive Motors
C/
W
B/
V
A/U
W
V
U
S
IN+
S
IN-
CO
S
+
CO
S
-
DATA+
DATA-
+5
V
DC
ECOM
GREEN
W
HT/GREEN
GRAY
W
HT/GRAY
BLACK
W
HT/BLACK
RED
W
HT/RED
3
4
5
6
1
2
9
10
1
2
3
4
9
10
7
8
14
12
ORANGE
W
HT/ORANGE
11
13
11
4
3
2
1
Green/Yellow
Blue
Black
Brown
GND
S
hield
W
V
U
T
S
-
COM
BLUE
7
8
5
6
CLK+
CLK-
BRO
W
N
W
HT/BRO
W
N
–
T
S
+
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Motor Power
(MP) Connector
Cable Shield
Clamp
Note 10
Note 15
RDB-B
xxxx
Direct Drive
Servo Motors with
High Resolution Feedback
Motor Feedback
(MF) Connector
Three-phase
Motor Power
Motor
Feedback
Thermistor
2090-K6CK-KENDAT
Feedback Module
Refer to low profile connector
illustration (lower left)
for proper grounding technique.
2090-K6CK-KENDAT
Low-profile Feedback Module
Grounding Technique for
Feedback Cable Shield
Turn clamp over to hold
small cables secure.
Exposed shield secured
under clamp.
Clamp Screws (2)
Clamp
Refer to table on
2090-XXNFMF-S
xx
(standard)
or
2090-CFBM7DF-CDAF
xx
(continuous-flex)
Flying-lead Feedback Cable
Notes 16
2090-XXNPMF-
xx
S
xx
(standard)
or 2090-CPWM7DF-
xx
AF
xx
(continuous-flex)
Motor Power Cable
IAM (inverter) or AM
Module
Note 20
Refer to Low Profile EnDat Feedback Module Installation Instructions,
, for connector kit specifications.
Summary of Contents for Allen-Bradley 2094-BC01-M01-S
Page 4: ...4 Rockwell Automation Publication 2094 UM001D EN P May 2010 Summary of Changes Notes...
Page 10: ...10 Rockwell Automation Publication 2094 UM001D EN P May 2010 Table of Contents Notes...
Page 278: ...278 Rockwell Automation Publication 2094 UM001D EN P May 2010 Index Notes...
Page 279: ......