154
Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
Chapter 6
Configure and Start Up the Kinetix 6000 Drive System
Change Parameters with the HIM Module
When using the HIM module to monitor or change parameters, use the up and
down arrows (
∧
and
∨
) to arrive at selections. Refer to the instructions that
came with your HIM module for more information.
Follow these steps to monitor or change parameters with the HIM module.
1.
Select
parameter, press
↵
.
2.
Select I/O AM1 Group (for IAM module), press
↵
.
3.
Select Analog
Outputs, press
↵
.
a. Analog Output 1 is displayed, press
↵
.
b. For Analog Output 2 use arrows to select, press
↵
.
4.
Press Sel.
5.
Enter parameter number, press
↵
.
Monitor System Variables with Analog Test Points
There are two analog output test points accessible from the IOD 26-pin
connector on the IAM and AM module.
Table 81 - IAM/AM I/O 26-pin (IOD) Connector
Figure 80 - Pin Orientation for 26-pin I/O (IOD) Connector
Refer to Analog Outputs on
for signal specifications.
IOD Pin
Description
Signal
23
Analog output 0
DAC0
24
Analog output common
DAC_COM
25
Analog output 1
DAC1
26
Analog output common
DAC_COM
Pin 18
Pin 26
Pin 1
Pin 9
Pin 10
Pin 19
26-pin IAM/AM
I/O Connector
Summary of Contents for Allen-Bradley 2094-BC01-M01-S
Page 4: ...4 Rockwell Automation Publication 2094 UM001D EN P May 2010 Summary of Changes Notes...
Page 10: ...10 Rockwell Automation Publication 2094 UM001D EN P May 2010 Table of Contents Notes...
Page 278: ...278 Rockwell Automation Publication 2094 UM001D EN P May 2010 Index Notes...
Page 279: ......