Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
155
Configure and Start Up the Kinetix 6000 Drive System
Chapter
6
Parameters begin with a variable to identify a specific axis by slot number, as
follows:
•
IAM module = 0 for parameters 0…999
•
1st AM module = 1 for parameters 1000…1999
•
2nd AM module = 2 for parameters 2000…2999 and so on
•
7th AM module = 7 for parameter 7000…7999
Table 82 - Monitor System Variables
The value entered in Scale Parameter will scale the analog output so that you can
get a full scale reading of the specific parameter for the dynamic range or values
you are testing.
For linear scaling specifications, refer to the table on
Table 83 - Monitor Dynamic System Variables
Analog
Output
Controlling Parameter
Scale Parameter
Parameter Number
(1)
Default Value
(1)
Parameter Number
(1)
Default Value
1
x
681
xx
40
x
682
0.0060
2
x
683
xx
84
x
684
0.1000
(1)
x
= slot number
Attribute
Parameter Number
(1)
(1)
x
= slot number.
Velocity feedback
xx
40
Velocity commanded
xx
36
Torque feedback
xx
84
Torque commanded
xx
80