![Rockwell Automation Allen-Bradley 2094-BC01-M01-S User Manual Download Page 201](http://html1.mh-extra.com/html/rockwell-automation/allen-bradley-2094-bc01-m01-s/allen-bradley-2094-bc01-m01-s_user-manual_1475821201.webp)
Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
201
Interconnect Diagrams
Appendix B
Power Wiring Examples
Figure 87
Single IAM Module with 2094-AL09 or 2094-BL02 LIM Module
L3
L2
L1
DC-
DC+
L3
L2
L1
L2
L1
CTRL 2
CTRL 1
L3'
L2'
L1'
1
2
1
2
3
4
5
6
1
2
BR-
MBRK -
MBRK +
COM
PWR
DBRK -
DBRK +
BR-
MBRK_PWR
MBRK_COM
MBRK_PWR
MBRK_COM
CONT EN-
CONT EN+
W
V
U
24-26
13
20-22
4
4
3
2
1
IO_PWR
COIL_A1
IO_COM
COIL_A2
1
2
3
4
BR+
BR+
1
2
6
5
4
3
2
1
Control Power
(CPD) Connector
* Indicates User Supplied Component
Contactor Enable
(CED) Connector
Note 14
Motor Brake
Connections
Resistive Brake
Connections
24V DC Output
(PSL) Connector
Motor/Resistive
Brake (BC) Connector
Three-phase
Motor Power
Connections
Note 16
Motor Power
(MP) Connector
Cable Shield
Clamp
2094-AC
xx
-M
xx
-
x
or
2094-BC
xx
-M
xx
-
x
IAM Module
Bonded Cabinet
Ground Bus*
VAC LINE Three-phase
(IPL) Input
195…264V AC RMS
or 324…528V AC RMS
Power Rail
Ground Stud
Ground
VAC LOAD Three-phase
(OPL) Output
195…264V AC RMS
or 324…528V AC RMS
STOP *
I/O (IOL)
Connector
2094-AL09 or 2094-BL02
Line Interface Module
DC Bus
and
Three-phase
Input (IPD)
Connector
Single-phase (CPL) Output
195…264V AC RMS
Input Fusing *
Refer to table on
for note information.
Summary of Contents for Allen-Bradley 2094-BC01-M01-S
Page 4: ...4 Rockwell Automation Publication 2094 UM001D EN P May 2010 Summary of Changes Notes...
Page 10: ...10 Rockwell Automation Publication 2094 UM001D EN P May 2010 Table of Contents Notes...
Page 278: ...278 Rockwell Automation Publication 2094 UM001D EN P May 2010 Index Notes...
Page 279: ......