92
Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
Chapter 5
Connecting the Kinetix 6000 Drive System
Table 49 - IAM/AM Power Wiring Requirements
Table 50 - Shunt Module Power Wiring Requirements
Kinetix 6000 Drive
Cat. No.
Description
Connects to Terminals
Recommended
Wire Size
mm
2
(AWG)
Strip Length
mm (in.)
Torque Value
N•m (lb•in)
Pin
Signal
2094-AC05-M
xx-x,
2094-AC09-M02-
x,
2094-BC01-M
xx
-
x,
2094-BC02-M02-
x,
2094-AMP5-
x
,
2094-AM01-
x,
2094-AM02-
x
,
2094-BMP5-
x
,
2094-BM01-
x,
2094-BM02-
x
Motor power
MP-4
MP-3
MP-2
MP-1
Motor power
cable depends
on motor/drive
combination.
6…1.5
(10…16)
10 (0.38)
0.5…0.6
(4.4…5.3)
2094-AC16-M03-
x,
2094-AC32-M05-
x,
2094-BC04-M03-
x,
2094-AM03-
x
,
2094-AM05-
x,
2094-BM03-
x
10…1.5
(8…16)
10 (0.38)
1.2…1.5
(10.6…13.2)
2094-BC07-M05-
x,
2094-BM05-
x
30…2.5
(3…14)
16 (0.63)
2.4…3.0
(21.6…26.5)
IAM or AM
(230 or 460V)
2094-
x
C
xx
-M
xx
-
x
and
2094-
x
M
xx
-
x
Brake power
BC-6
BC-5
BC-4
BC-3
BC-2
BC-1
MBRK-
MBRK+
COM
PWR
DBRK-
DBRK+
0.75 (18)
10 (0.38)
0.22…0.25
(1.9…2.2)
IAM or AM
(230 or 460V)
2094-
x
C
xx
-M
xx
-S
and
2094-
x
M
xx
-S
Safe-off
SO-1
SO-2
SO-3
SO-4
SO-5
SO-6
SO-7
SO-8
SO-9
N/A
N/A
FDBK2+
FDBK2-
FDBK1+
FDBK1-
SAFETY
SAFETY
ENABLE-
SAFETY
24V +
24V_COM
0.75 (18)
(stranded wire
with ferrule)
1.5 (16)
(solid wire)
7.0 (0.275)
0.235 (2.0)
W
V
U
Cat. No.
Description
Connects to Terminals
Recommended
Wire Size
mm
2
(AWG)
Torque Value
N•m (lb•in)
Pin
Signal
2094-BSP2
Shunt module
(230/460V)
1394-SR
xxxx
External passive
shunt module
RC-1
DC+
10 (8)
(1)
1.2…1.5
(10.6…13.2)
RC-2
INT
RC-3
COL
Thermal switch
TS-1
TS1
0.75 (18)
0.22…0.25
(1.9…2.2)
TS-2
TS2
(1) 105 °C (221 °F), 600V.
Summary of Contents for Allen-Bradley 2094-BC01-M01-S
Page 4: ...4 Rockwell Automation Publication 2094 UM001D EN P May 2010 Summary of Changes Notes...
Page 10: ...10 Rockwell Automation Publication 2094 UM001D EN P May 2010 Table of Contents Notes...
Page 278: ...278 Rockwell Automation Publication 2094 UM001D EN P May 2010 Index Notes...
Page 279: ......