Kinetix 6000 Connector Data
Chapter
4
Feedback Specifications
The IAM and AM modules can accept motor and auxiliary feedback signals from
these types of encoders:
•
Stegmann Hiperface
•
TTL or Sine/Cosine with index pulse and Hall commutation
•
Resolver Transmitter TR = 0.25 (motor feedback only)
Motor feedback from Heidenhain EnDat high-resolution encoders is also
accepted, but only when using drive firmware revision 1.116 and the
2090-K6CK-KENDAT low-profile feedback module for EnDat to Hiperface
conversion.
Absolute Position Feature
The drive’s absolute position feature tracks the position of the motor, within
±2048 turns, while the drive is powered off. The absolute position feature is
available with only multi-turn (-M or -V) encoders, for example, motor catalog
number MPL-B310P-M.
Figure 35 - Absolute Position Retention Limit
Position at Power Down
+2048
+1024
-2048
-1024
4096 Turns, Kinetix 6000 Drives