6 Flow meters
Manual ERZ 2000-NG · EN07 · 2019, May 13th
257
Menu GV Orifice plate shows some
GW Extremal values
of the
Orifice calculation
for
an
expanded type plate.
GW01
shows the flow rate coefficient C and
GW02
shows the Reynolds number Re
D
in the design point of the orifice meter.
GW04
and
GW05
contain the maximum mass flow rate and the maximum flow rate at base con-
ditions.
GW14
and
GW15
show the corresponding minimum values.
Figure 187: Menu GX Pipe roughness
GX Roughness of tube
influences the velocity profile and thus the flow rate depend-
ing on delta-p. If this correction is activated (
GX04
), a correction for the roughness
entered in
GX05
is considered according to GOST (see below).
Figure 188: Menu GY Abrasion of orifice edge
If "Calculation" is set in coordinate
GY04
(instead of "off" or "default"), the abrasion of
orifice edge according to GOST is factored in. For this purpose,
GY05 Point in time
of the determination of
GY06 Beginning radius
of the inside diameter of the orifice
plate must be defined.
Summary of Contents for ERZ2000-NG
Page 10: ......
Page 68: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 58 Figure 44 Menu LA Overview...
Page 69: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 59 Figure 45 Menu LB Totalizer BM1...
Page 77: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 67 Figure 51 Overview System sub menu...
Page 241: ...6 Flow meters Manual ERZ 2000 NG EN07 2019 May 13th 231 Figure 167 Interface module C34...
Page 340: ...8 Overview Coordinates Manual ERZ 2000 NG EN07 2019 May 13th 330 8 5 6 TSV export...
Page 453: ...Certificates Manual ERZ 2000 NG EN07 2019 May 13th 443...