7 Parameter of the gas
Manual ERZ 2000-NG · EN07 · 2019, May 13th
270
Note
The Joule-Thomson coefficient
μ
can be positive or negative. For air, the tem-
perature increases with a pressure increase (heating up of the valve with an air
pump) and decreases as pressure decreases. With natural gas, the Joule-
Thomson coefficient
μ
has the same algebraic sign; the temperature decreases
as pressure decreases. In order to prevent adverse effects of the gas pressure
regulating system due to excessively low temperatures, the compressed gas is
often preheated.
Due to the identical structure of the preceding menus, no further representations and
explanations are provided here.