1 About this manual
Manual ERZ 2000-NG · EN07 · 2019, May 13th
24
Figure 8: ER Signature menu
Note
Access to the coordinates ER01 Signing and ER03 New key is under cali-
bration protection and they can only be initiated or changed with an open
calibration switch.
The signing method is selected in the coordinate
ER01 Signature
.
x
No signing
"no"
x
Short signing code
"ECDSA192"
x
Long signing code
"ECDSA192"
Note
The DVGW (Deutscher Verein des Gas- und Wasserfaches) recommends
using the RMD160 method for custody transfer applications.
A new key is generated in the coordinate
ER03 New key
.
Generation of a new key is generally recommended when the ERZ2000-NG is left
unsupervised with an open calibration switch for an extended time, e.g. during re-
pairs.