2 Introduction
Manual ERZ 2000-NG · EN07 · 2019, May 13th
65
Figure 48: Menu LV Customer-specific totalizers set A
The customer-specific totalizers have a similar configuration to the "normal" totaliz-
ers. In coordinate
LV31 Assignm. main/dist.
, a selection between "Undisturbed on-
ly", "Disturbed only " and "Always" can be made for the
Totalizers operation
. With
"Only undisturbed", for example, the customer totalizers only run when the ERZ2000-
NG status is undisturbed. The selection of totalizers source(s) is made in coordinate
LV32 Assignm. to BM
the customer totalizers run only when Billing mode 1 or 2 is
active. A totalizers designation is assigned in coordinate
LV33 Description
.
Menu
LW Customer-specific
totalizers
set B
is configured analogously to menu LV.
Menu
LX Setting customer-specific totalizers
is comparable to the "normal" setting
of totalizers (see above).