6 Flow meters
Manual ERZ 2000-NG · EN07 · 2019, May 13th
197
There are 16 support point pairs for forward operation and the polynomial coefficients
(at the end of the table). If "without correction" is entered in
GD07
for
GD Determina-
tion of characteristic
, the values still used again without correction. This corre-
sponds to the value "0" in all defaults of the correction points. The entered values are
adopted accordingly if the parameter is set to "with correction".
Figure 133: Charac-
teristic correction
shows how a correction takes place for the values provided in
Ta-
ble 5: Support point correction
(
Note
: the values match the values in
Figure 132:
Menu GE Forward operation characteristic curve correction)
.
Support point [%]
5
10
25
40
70
100
Deviation [%]
1.0
0.5
0.2
0.0
0.1
0.0
Table 5: Support point correction
Figure 133: Characteristic correction
The deviation is approximated linearly between the interpolation points.
Figure 133:
Characteristic correction
indicates the deviation 0.3% for the operating point 20%.
Therefore, the correction is calculated as follows:
݀݅ݏ݈ܽݕ݁݀ݒ݈ܽݑ݁ ൌ
݉݁ܽݏݑݎ݁݀ݒ݈ܽݑ݁
ሺͳ ݀݁ݒ݅ܽݐ݅݊ሻ
ൌ
݉݁ܽݏݑݎ݁݀ ݒ݈ܽݑ݁
ሺͳ ͲǤ͵ሻ
ൎ ݉݁ܽݏݑݎ݁݀ݒ݈ܽݑ݁ ή Ͳǡͻͻ
Summary of Contents for ERZ2000-NG
Page 10: ......
Page 68: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 58 Figure 44 Menu LA Overview...
Page 69: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 59 Figure 45 Menu LB Totalizer BM1...
Page 77: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 67 Figure 51 Overview System sub menu...
Page 241: ...6 Flow meters Manual ERZ 2000 NG EN07 2019 May 13th 231 Figure 167 Interface module C34...
Page 340: ...8 Overview Coordinates Manual ERZ 2000 NG EN07 2019 May 13th 330 8 5 6 TSV export...
Page 453: ...Certificates Manual ERZ 2000 NG EN07 2019 May 13th 443...