![background image](http://html1.mh-extra.com/html/rmg/erz2000-ng/erz2000-ng_operating-manual_1467424093.webp)
2 Introduction
Manual ERZ 2000-NG · EN07 · 2019, May 13th
83
Figure 68: Free progarmmable archive
Assignment to the archive:
4 control totalizers, 8 special measurement values and 6 special totalizers can be
stored in Archive 10. Archive group 16, in which the free inputs can be stored, can be
hidden in menu
ID DSfG entity recording
with "no" for the retrieval software with
coordinate
ID04 AG 16 Visible
.
Deletion of archives, log books, change buffer, etc.
In menu
E Mode
, sub-menu
EM Erasing procedures
(
Figure 69: EM Erasing proce-
dures menu
), archives, log books, etc. can be deleted. As a
Super user
(
see chapter
2.3 Access protection for data and
settings) the coordinates
EM10 Clear log
,
EM11
Clear changes
,
EM12 Clear archive
(DSfG archive of the flow computing and regis-
tration instance, as well as the DSfG log book),
EM13 Hour/day reset
(DSfG Archive
for the highest load),
EM14 Drag indic. reset
(max and min values of all drag point-
ers, values are set to the current values),
EM15 accuracy test init
(operating point
testing) and
EM16 Clear exceptions
are activated.
Summary of Contents for ERZ2000-NG
Page 10: ......
Page 68: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 58 Figure 44 Menu LA Overview...
Page 69: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 59 Figure 45 Menu LB Totalizer BM1...
Page 77: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 67 Figure 51 Overview System sub menu...
Page 241: ...6 Flow meters Manual ERZ 2000 NG EN07 2019 May 13th 231 Figure 167 Interface module C34...
Page 340: ...8 Overview Coordinates Manual ERZ 2000 NG EN07 2019 May 13th 330 8 5 6 TSV export...
Page 453: ...Certificates Manual ERZ 2000 NG EN07 2019 May 13th 443...