6 Flow meters
Manual ERZ 2000-NG · EN07 · 2019, May 13th
226
6.4 Connection of USZs via Instance F
There has been a desire for some time to standardize the connection of ultrasonic
meters to further electronic evaluation units. In particular, the desire arose to
transmit "all" data determined by an ultrasonic meter, i.e. measurements and
status information or diagnostic data, in the same manner. Recently, the connection
via Instance F crystallized as a standard.
6.4.1
Explanation of the term Instance F
Ultrasonic meters normally do not have dedicated DSfG bus access. Therefore, In-
stance F was implemented externally via a DSfG-compatible flow rate computer. The
data required for this is transmitted via Modbus between ultrasonic meters and flow
rate computers. This Modbus protocol is frequently already called Instance F, alt-
hough it is only prepared for the data required for the DSfG Instance F. In the
ERZ2000-NG
, the appropriate settings are found in menu
VK Modbus master USM
.
The corresponding register plots are provided in menu
VJ Register expressions
.
Figure 161: Data exchange between ERZ2000-NG and USM GT400
Summary of Contents for ERZ2000-NG
Page 10: ......
Page 68: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 58 Figure 44 Menu LA Overview...
Page 69: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 59 Figure 45 Menu LB Totalizer BM1...
Page 77: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 67 Figure 51 Overview System sub menu...
Page 241: ...6 Flow meters Manual ERZ 2000 NG EN07 2019 May 13th 231 Figure 167 Interface module C34...
Page 340: ...8 Overview Coordinates Manual ERZ 2000 NG EN07 2019 May 13th 330 8 5 6 TSV export...
Page 453: ...Certificates Manual ERZ 2000 NG EN07 2019 May 13th 443...