6 Flow meters
Manual ERZ 2000-NG · EN07 · 2019, May 13th
249
GA10 Substance orifice
GA11 Substance pipe
Selection options
Coefficients
A
B
Off
-
-
Linear
-
-
GOST
-
-
Steel I
12.60
0.0043
Steel II
12.42
0.0034
Steel III
12.05
0.0035
Steel IV
10.52
0.0031
Steel V
17.00
0.0038
Steel VI
16.30
0.0116
Bronze SnBz4
17.01
0.0040
Copper E-Cu
16.13
0.0038
Gunmetal Rg9
16.13
0.0038
Brass Ms63
17.52
0.0089
Nickel
14.08
0.0028
Hastelloy C
10.87
0.0033
Table 7: Temperature correction for orifice plate and pipe
Off
The corresponding temperature correction is switched off.
Linear
The correction factor
GA03 T-crr.fact. orifice
or
GA04 T-crr.fact.
p
ipe
is calculated
with the linear heat expansion coefficient
GA05 lin.expans. orifice
or
GA06
lin.expans. pipe
.
ܩܣͲ͵ ൌ ͳ Ͳͷ ڄ ሺܶ െ ʹͲሻ
The temperature
T
is relative to °C; the Pipe T-calc.fact takes place analogously.
Material selection
The correction factor
GA03 T-crr.fact. orifice
or
GA04 T-calc.fact
p
ipe
is calculated
with a proximity equation and coefficients A and B.
ܩܣͲ͵ ൌ ͳ ሺܣ ڄ ሺܶ െ ʹͲሻ ܤ ڄ ሺܶ െ ʹͲሻ
ଶ
ሻ ڄ ͳͲ
ି
Summary of Contents for ERZ2000-NG
Page 10: ......
Page 68: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 58 Figure 44 Menu LA Overview...
Page 69: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 59 Figure 45 Menu LB Totalizer BM1...
Page 77: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 67 Figure 51 Overview System sub menu...
Page 241: ...6 Flow meters Manual ERZ 2000 NG EN07 2019 May 13th 231 Figure 167 Interface module C34...
Page 340: ...8 Overview Coordinates Manual ERZ 2000 NG EN07 2019 May 13th 330 8 5 6 TSV export...
Page 453: ...Certificates Manual ERZ 2000 NG EN07 2019 May 13th 443...