9 Faults
Manual ERZ 2000-NG · EN07 · 2019, May 13th
334
The behavior of the corresponding contact can be changed with
JA22
and
JA23
.
Real-time =
as before
Elongated =
the elongation time can be adjusted in
JA24
Sustain
=
the message must be deleted manually
In coordinate
JA28 Bits flux control
, all faults are investigated according to logical
associations and displayed as collective alarms in register 474 (and 9118) in a spe-
cial bit.
Bit 0:
Delta P alarms
Bit 1:
Gas composition alarms
Bit 2:
Temperature alarms
Bit 3:
Pressure alarms
Bit 4:
Alarms associated with the volume
Bit 5:
Alarms associated with the volume at measurement conditions
Warning and alarm messages can be acknowledged with a contact input. The
assignment takes place in coordinate
JA31
.