background image

Portable

 

Thermo

Hygrometer

 

Operation

 

Manual

   

98871/98873/98874/98875/98877

   

 

The

 

meter

 

simultaneously

 

measures

 

and

 

displays

 

Temp.

 

and

 

RH

 

,calculate

 

dew

 

point,

 

wet

 

bulb

 

temperature

 

in

 

seconds.

 

Easy

 

operation,

 

meter

 

powered

 

by

 

three

 

1.5

 

volt

 

batteries,

 

receptacle

 

device

 

is

 

built

in

 

for

 

tripod

 

mountable

 

enable

 

to

 

do

 

long

 

time

 

logging

 

purposes.

 

 

SPECIFICATION:

 

 

Temp.

 

range:

 ‐

20~50C

 

(

 ‐

4~122F)

 

,

 

accuracy

 

:

 

±

0.6C

 

 

RH%

 

range:

 

0.1~99.9%

 

,

 

accuracy:

 

±

3%(10~90%RH),

 

others

 

±

5%RH

 

 

Temperature

 

measurement:

 

Ambient

 

Temp.

 

Dew

 

Point

 

Temp.

 

Wet

 

Bulb

 

Temp.

 

 

Heat

 

index,

 

WBGT

 

temperature

 

measurement(98875.98877)

 

 

High/Low

 

Temp.

 

&

 

RH

 

alarm

 

threshold

 

setting

   

 

Function:

 

Maximum,

 

Minimum

 

,

 

Average

 

and

 

Recall

   

 

Manually

 

record

 

up

 

to

 

99

 

points

 

in

 

meter(98873.98874.98877)

 

 

On

 

line

 

recording

 

up

 

to

 

64,000

 

points

 

to

 

PC(98875)

 

 

Dimension:

 

160x60x40mm

 

(

 

Meter

 

),

 

Sensor

 

tip

 

(

 

31mm)

 

 

Power

 

:

   

AAA

 

Volt

 

battery

 

x

 

3

 

pcs

   

 

Self

calibration

 

RH%

 

(

 

Optional

 

function

 

)

 

 

Back

light

 

function(Optional)

 

 

External

 

probe

 

temp(98874

 

only)

 

Supplied:

 

Battery

 

,

 

Meter

 

,

 

operation

 

manual.

 

USB

 

cable

 

.

 

On

 

line

 

logging

 

software(98875

 

only)

 

EXT.

 

probe

 

(98874

 

only)

 

 

 

 
 
 
 

 

 
 

 

 
 

 

 
 

 

Portable

 

meter

                               

Main

 

screen

 

of

 

on

 

line

 

logging

   

 

KEY

 

PAD

 

PWR.

 

       

Turn

 

on

 

or

 

off

 

,

 

bell

 

icon

 

activate

 

HOLD

 

       

Freeze

 

current

 

readings.

 

Forward

 

review

 

or

 

Increase

 

digit

 

Backlight

 

 

Optional

 

(

 

Backlight

 

function)

 

.

 

Decrease

 

digit

 

and

 

Back

 

review.

 

Max.Min.

 

 

Review

 

Max.

 

Min.

 

AVG

 

readings

 

and

 

toggle

 

RH,

 

Temp.

 

Hi,Lo

 

alarm

 

threshold

   

setting

 

MODE.

       

Toggle

 

Temp.

 

DP.

 

WB

 

temperature

 

display.

 

Recall

 

99

 

points

 

memory

 

data,

 

EXT.

   

temp.

 

mode.

 

SET.

 

           

Manually

 

record

 

99

 

memory

 

point

 

in

 

meter.

 

Enter

 

Hi.Lo

 

alarm

 

threshold

 

setting

 

and

 

save

 

to

 

escape.

 

Unit.

 

         

Toggle

 

Temperature

 

unit

 

C

 

and

 

F.

 

While

 

Hi.Lo

 

setting,

 

toggle

 

Temp.

 

RH

 

setting

 

mode.

 

 

 

 

SPECIFICATION

 

 

98871

 

98873

 

98875

 

98874

 

98877

 

Temp.

 

range

 

20.0~50.0

(

4.0~122.0

)

 

         

Accuracy

 

±0.6

 

External

 

Temp.

 

probe

 

N/A

 

32.dx150mm

 

probe

 

External

 

Temp.

 

range

 

N/A

 

40~100

 

RH%

 

range

 

0.1%~99.9%

 

       

Accuracy

 

±3%(10~90%),others

 

±5%

 

HI/WBGT

 

Temp.

 

N/A

 

YES

 

N/A

 

YES

 

DP/WB

 

Temp.

 

N/A

 

YES

 

Self

Calibration

 

N/A

 

Optional

 

YES

 

HI/LO

 

Alarm

 

N/A

 

YES

 

Memory

 

N/A

 

99poin

ts

 

Online

 

64000

 

points

 

99points

 

USB

 

interface

 

N/A

 

YES

 

N/A

 

Operating

 

Temp.

 

&RH%

 

0~50

,<80%RH

 

Power

 

AAA

 

x3

 

pcs

 

Meter

 

size

 

160x55x29mm(Meter),

 

Sensor

 

tip(31mm)

 

 

OPERATION

 

POWER

 

ON/OFF:

 

Short

 

press

 

”PWR”

 

button

 

to

 

turn

 

on

 

the

 

meter,

 

press

 

and

 

hold

 

for

 

2

 

seconds

 

to

 

turn

 

off

 

the

 

meter.

 

 

MAX/MIN/AVG:

 

Short

 

press

 

MAX/MIN

 

button

 

to

 

cycle

 

display

 

Maximum

 

,

 

Minimum

 

,

 

Average

 

Temperature

 

and

 

RH

   

from

 

powered

 

on.

 

 

CHANGE

 

DEGREE

 

/

:

 

Short

 

press

 

UNIT

 

button

 

to

 

switch

 

 

and

 

℉.

 

 

DP/WB/HI/WBGT:

 

Short

 

press

 

MODE

 

button

 

to

 

toggle

 

current

 

temperature,

 

DP(Dew

 

point),

 

WB(Wet

 

bulb

 

temperate)

 

HI(Heat

 

index),

 

WBGT

 

at

 

the

 

second

 

layer(98875.98877only)

 

 

   

EXT

 

TEMP.(98874

 

only):

 

Long

 

press

 

MODE

 

to

 

show

 

EXT.

 

Temp.

 

 

RECORD

 

99

 

points(98873/98874/98877

 

only):

 

Short

 

press

 

SET

 

button

 

to

 

save

 

current

 

readings

 

(

 

Temp.

 

RH),

 

REC

 

icon

 

shows

 

next

 

to

 

RH%

 

reading

 

and

 

record

 

number

 

shows

 

next

 

to

 

Temperature

 

reading

 

about

 

2

 

seconds

 

then

 

disappear.

 

Meter

 

may

 

store

 

up

 

to

 

99

 

points.(98873.98874.98877

 

only)

 

Recall

 

recorded

 

data:

 

press

 

and

 

hold

 

MODE

 

button

 

to

 

review

 

memory

 

Temp.

 

RH

 

and

 

record

 

number,

 

keep

 

pressing

 

HOLD

 

button

 

to

 

review

 

next

 

data

 

,

 

press

 

BKLT

 

button

 

to

 

review

 

back

 

the

 

last

 

data.

 

Long

 

press

 

MODE

 

button

 

again

 

,

 

to

 

escape

 

memory

 

function

 

.

 

 

CLEAR

 

MEMORY

 

:

   

Under

 

data

 

record

 

long

 

press

 

SET

 

button

 

to

 

clear

 

the

 

memory.

 

 

FREEZE

 

READING:

 

Short

 

press

 

HOLD”

 

button

 

under

 

normal

 

measurement,

 

HLD

 

icon

 

shows

 

on

 

screen

 

to

 

freeze

 

current

 

readings.

 

 

BACKLIGHT:

 

Reviews: