6 Flow meters
Manual ERZ 2000-NG · EN07 · 2019, May 13th
190
simulated for test purposes.
The frequency is adjusted with coordinate
GB55
Freq.turbinesim.
USC, HF1-ch.
Vm is delivered via DZU protocol,
HF input is used for comparison
USC, HF2-ch. 1/1 Vm is delivered via DZU protocol,
HF inputs are used for comparison
USC, LF1-ch.
Vm is delivered via DZU protocol,
LF input is used for comparison
The following must be considered for the reporting of alarms or warnings: If ENCO is
at the beginning with a 2-channel operating mode, with HF measuring inputs at the
end, a warning with separate message number is issued instead of an alarm in case
of a pulse failure or pulse comparison error.
Logic of the synchronization monitoring
The synchronization monitoring is focused on the software comparison between two
possible inputs for volume formation. The comparison takes place automatically with
more than 1 input. The synchronization monitoring checks all combinations with more
than one input and is not limited tot he comparison between Vo and LF input. The
following table provides an overview of the functions in error-free operation. In case
of an error, the ERZ2000-NG uses the undisturbed signal or, with 3 input signals, it
automatically switches over to the appropriate signal.
Operating
mode
Errors
Vc
DZU
error
HW
Comp.
SW
Comparison
QB
Bill.
Vm
Bill.
Kv
Use
Vo
alarm
Off
Off
Off
Metering mode
Vo
Vo
Vo, LF1-ch.
alarm
Off
Off
Vo -- LF1-ch.
Metering mode
Vo
Vo
LF1-ch., Vo
warning Off
Off
LF1-ch. -- Vo
Metering mode
LF
meas. ch.
Vo, HF-1ch.
alarm
Off
Off
Vo -- HF-1ch.
HF Signal
Vo
Vo
HF1-ch., Vo
warning Off
Off
HF1-ch.
–
Vo
HF Signal
HF Signal
meas. ch.
Vo, HF2-ch. 1/1
alarm
Off
1:1
Vo
–
HF meas. HF meas. signal Vo
Vo
HF2-ch. 1/1, Vo
warning Off
1:1
HF meas.
–
Vo HF meas. signal HF meas. signal meas. ch.
Vo, HF2-ch. X/Y
alarm
Off
X:Y
Vo
–
HF meas. HF meas. signal Vo
Vo
HF2-ch. X/Y, Vo
warning Off
X:Y
HFmeas.
–
Vo HF meas. signal HF meas. signal meas. ch.
HF2-ch. 1/1
Off
Off
1:1
Meas.-- comp. HF meas. signal HF meas. signal meas. ch.
HF2-ch. X/Y
Off
Off
X:Y
Meas.-- comp. HF meas. signal HF meas. signal meas. ch.
HF LF
Off
Off
Off
HF -- LF
HF Signal
HF meas. signal meas. ch.
HF1-ch.
Off
Off
Off
Off
HF Signal
HF Signal
meas. ch.
LF1-ch.
Off
Off
Off
Off
Metering mode
LF Signal
meas. ch.
DZU
Off
alarm
Off
Off
DZU
DZU
DZU
IGM
Off
Off
Off
Off
IGM
IGM
IGM
Summary of Contents for ERZ2000-NG
Page 10: ......
Page 68: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 58 Figure 44 Menu LA Overview...
Page 69: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 59 Figure 45 Menu LB Totalizer BM1...
Page 77: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 67 Figure 51 Overview System sub menu...
Page 241: ...6 Flow meters Manual ERZ 2000 NG EN07 2019 May 13th 231 Figure 167 Interface module C34...
Page 340: ...8 Overview Coordinates Manual ERZ 2000 NG EN07 2019 May 13th 330 8 5 6 TSV export...
Page 453: ...Certificates Manual ERZ 2000 NG EN07 2019 May 13th 443...