7 Parameter of the gas
Manual ERZ 2000-NG · EN07 · 2019, May 13th
265
AD02
: An arrow after the input value indicates the origin of the value
–
in this case,
from the default of
AD05
, because the operating mode is set to "default". A different
operating mode can be selected in
AD03
(e.g. from default, DSfG, RMG bus, lin. fre-
quency response, 1st order polynomial, 2nd order polynomial, 3rd order polynomial,
4-20mA coeff., 0-20mA coeff., 4-20mA limit value, 0-20mA limit value, table value,
ISO 6976, Modbus, GPA 2172-96, EGO Modbus, univ.Modb.master).
If, for example, a different operating mode is selected, e.g. the reference to a current
input, which is assigned under
AD19
, a jump to there can take place directly via the
link, i.e. the link "NA01" (single click), see
Figure 194: Menu AD Calorific value, dif-
ferent operating mode
.
Figure 194: Menu AD Calorific value, different operating mode
When the operation mode is set to default, the source is switched off (i.e. set to "off");
otherwise, the current inputs 1-12, frequency inputs 1-8 and the input possibility via
HART can also be selected with current inputs 1-12.
The value specified in
AD44
is maintained at a constant level while the test gas is
activated.
AD46
specified the maximum permissible deviation.
Summary of Contents for ERZ2000-NG
Page 10: ......
Page 68: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 58 Figure 44 Menu LA Overview...
Page 69: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 59 Figure 45 Menu LB Totalizer BM1...
Page 77: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 67 Figure 51 Overview System sub menu...
Page 241: ...6 Flow meters Manual ERZ 2000 NG EN07 2019 May 13th 231 Figure 167 Interface module C34...
Page 340: ...8 Overview Coordinates Manual ERZ 2000 NG EN07 2019 May 13th 330 8 5 6 TSV export...
Page 453: ...Certificates Manual ERZ 2000 NG EN07 2019 May 13th 443...