3 Electrical connections
Manual ERZ 2000-NG · EN07 · 2019, May 13th
136
3.1.18 MF Pulse output 1
Figure 97: Menu MF Pulse output 1
This pulse output 1 is shown as an example for all 4 pulse outputs. Data, calculated
values, etc. can be selected with the various functions and mapped on the pulse out-
put.
Note
Since the frequency outputs 1 and 2 (port X3:1/2 and X3:3/4) are generally in-
tended for the volume flow at measurement and base conditions, these are
subject to the calibration lock, the other two frequency outputs are not.
The current situation with the pulse output, remainder in the buffer, output frequency,
etc. is displayed in coordinates
MF01 Pluse counter
to
MF04 Frequency
.
There are more possibilities in addition to the assignment of the output value to a
measurement in
MF10 Assignment meas.val.
:
x
direct output of the HF input
x
the number of pulses entered in line 20 can be output as a single pulse group
or cyclically, every second.