6 Flow meters
Manual ERZ 2000-NG · EN07 · 2019, May 13th
228
Figure 163: Connection of the RS 485-2 (22 +, 23 -) on the USM GT400
6.4.5
Configuration for COM6 and COM7
The optional COM 6 interface is required by the ERZ2000-NG for communication
with ultrasonic meters via Instance F. The DIL switches and jumpers for the RS 485
on the optional board required for this purpose must be adjusted as shown in
Figure
164: Option board configuration for use as COM6 and 7. S
witch 2 and switch 3 (when
counted from the left) of the DIL switches on the board must be set to ON. The posi-
tioning of the jumpers is indicated in the figure.
Then, the option board must be positioned in the COM6 and 7 slot, which is the first
from the right when viewing the display (
Figure 165: Slot of the option board for
COM6 and 7).