3 Electrical connections
Manual ERZ 2000-NG · EN07 · 2019, May 13th
137
Pulses are output in parallel with either the main totalizer or the disturbance totalizer
or always in coordinate
MF11 Assignment main/dist.
.
Assignment of the output mode with respect to the billing mode takes place in
MF12
Assignm. to BM
. The pulse accumulation takes place when the current billing mode
corresponds to one of the modes listed here. Example:
The setting here should be "134". The pulse accumulation takes place in billing
mode 1, 3 or 4. There is no accumulation in billing mode 2.
The ERZ2000-NG offers the possibility to change the pulse length at the pulse out-
puts. The coordinate
E15 strategy
is used for this purpose.
If pulses have accumulated during a measurement, they can be transferred in differ-
ent ways at a low sampling frequency (e.g. 10 Hz):
Strategy "rough":
Figure 98: Transfer frequency “rough”
Strategy "smooth":