Route 1 is assigned (V1 closed, V2 open Route 2). All positions of the valves be-
tween them, e.g. which can be provided for changeover, are not assigned to any bill-
ing mode.
The other contact options can be assigned in a similar manner:
x
2 ctc. 4*BM
Ctc 1 open
֜
Billing mode 1
Ctc 1 closed
֜
Billing mode 2
Ctc 2 open
֜
Billing mode 3
Ctc 2 closed
֜
Billing mode 4
x
4 ctc. 4*BM
Analog, see above.
x
Meas.->2 BM
x
Meas.->3 BM
x
Meas.->4 BM
Similar assignments can be assigned to a measurement here. As an example, the
temperature is selected here. This selection takes place in coordinate
EC05 As-
signment
by activating edit.
In the process, the
thresholds
should be entered in coordinates
EC06
to
EC08
. The
value settings in
Figure 139: Menu EC Billing mode
Fehler! Verweisquelle konnte
nicht gefunden werden.
produce:
Temperature < 50°C
֜
Billing mode 1
50°C < Temperature < 100°C
֜
Billing mode 2
100°C < Temperature < 150°C
֜
Billing mode 3
Temperature > 150°C
֜
Billing mode 4
x
Vo Direction
If "rev. permitted" is adjusted in coordinate
LN16 Vo Direction mode
, the Vo Direc-
tion can be used like a contact for switching to the billing modes.
x
DZU Direction
x
Flow direction
Summary of Contents for ERZ2000-NG
Page 10: ......
Page 68: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 58 Figure 44 Menu LA Overview...
Page 69: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 59 Figure 45 Menu LB Totalizer BM1...
Page 77: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 67 Figure 51 Overview System sub menu...
Page 241: ...6 Flow meters Manual ERZ 2000 NG EN07 2019 May 13th 231 Figure 167 Interface module C34...
Page 340: ...8 Overview Coordinates Manual ERZ 2000 NG EN07 2019 May 13th 330 8 5 6 TSV export...
Page 453: ...Certificates Manual ERZ 2000 NG EN07 2019 May 13th 443...