4 Communication and bus systems
Manual ERZ 2000-NG · EN07 · 2019, May 13th
163
The fill level indicators of the individual archive groups are checked to determine if
the
ID 03 Service request
number value entered here has been exceeded. An fault
message is issued if the value has been exceeded: H56-4 Service request, i.e. ser-
vice personnel needed urgently.
ID 04 AG 16 visible
controls whether archive group 16 (extra measurements) should
be visible for the central unit.
Text for identification of the corresponding archive group can be entered in coordi-
nates
ID 05
to
ID 12
.
A DSfG freeze telegram can be triggered with "yes" in
ID21
Attention freeze
. This
may be necessary if there is no revision switch in a station without MRG.
Archive contents can be exported with TSV files. Coordinate
ID22
offers settings op-
tions for design of headers and/or column headings.
DSfG:
The columns are overwritten with DSfG data element designations, e.g.
baae
.
Name:
The columns are overwritten with plain text, e.g.
corrected volume at
meas. cond. totalizer AM1
.
Note
The complete data element list of the registration instance of the
ERZ2000-NG is included in the device-internal documentation: see:
Documentation/II DSfG/1. Data element/b registration.
Summary of Contents for ERZ2000-NG
Page 10: ......
Page 68: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 58 Figure 44 Menu LA Overview...
Page 69: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 59 Figure 45 Menu LB Totalizer BM1...
Page 77: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 67 Figure 51 Overview System sub menu...
Page 241: ...6 Flow meters Manual ERZ 2000 NG EN07 2019 May 13th 231 Figure 167 Interface module C34...
Page 340: ...8 Overview Coordinates Manual ERZ 2000 NG EN07 2019 May 13th 330 8 5 6 TSV export...
Page 453: ...Certificates Manual ERZ 2000 NG EN07 2019 May 13th 443...