7 Parameter of the gas
Manual ERZ 2000-NG · EN07 · 2019, May 13th
278
7.3.4
GERG 88 S
Figure 201: Menu CD GERG 88 S
CD06 Consistency check
determines and displays deviations in the selected calcu-
lation method (AGA 8 92 DC in this case).
Exceeded limit values are monitored in Germany exclusively with use of GERG 88 S.
CD07 Limit mode
can be used to determine how further calculation takes place in
case of a limit value breach. If the limit value settings are exceeded (limit value
mode), further calculation "calculating with LV" takes place with the "real values"; this
is prescribed for official custody transfer applications in Germany. It is also possible
to continue to calculate with the default values for the K coefficient, "Default if LV".
According to the German version (pipeline quality gas according to ISO 12213-3),
"narrow" must be selected under
CD08 Limits
for official custody transfer applica-
tions with use of GERG 88 S. This corresponds to:
T of -10 to 65°C
P of 0 to 120 bar
dv of 0.55 to 0.8
Hs of 30 to 45 MJ/m³
Summary of Contents for ERZ2000-NG
Page 10: ......
Page 68: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 58 Figure 44 Menu LA Overview...
Page 69: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 59 Figure 45 Menu LB Totalizer BM1...
Page 77: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 67 Figure 51 Overview System sub menu...
Page 241: ...6 Flow meters Manual ERZ 2000 NG EN07 2019 May 13th 231 Figure 167 Interface module C34...
Page 340: ...8 Overview Coordinates Manual ERZ 2000 NG EN07 2019 May 13th 330 8 5 6 TSV export...
Page 453: ...Certificates Manual ERZ 2000 NG EN07 2019 May 13th 443...