Section 17 Smart Card Interface
SH7751 Group, SH7751R Group
Page 744 of 1128
R01UH0457EJ0301 Rev. 3.01
Sep 24, 2013
(3) Standby Mode and Clock
When switching between smart card interface mode and standby mode, the following procedures
should be used to maintain the clock duty cycle.
Switching from Smart Card Interface Mode to Standby Mode:
1. Set the SBP1IO and SBP1DT bits in SCSPTR1 to the values for the fixed output state in
standby mode.
2. Write 0 to the TE and RE bits in the serial control register (SCSCR1) to stop transmit/receive
operations. At the same time, set the CKE1 bit to the value for the fixed output state in standby
mode.
3. Write 0 to the CKE0 bit in SCSCR1 to stop the clock.
4. Wait for one serial clock cycle. During this period, the duty cycle is preserved and clock output
is fixed at the specified level.
5. Write H'00 to the serial mode register (SCSMR1) and smart card mode register (SCSMR1).
6. Make the transition to the standby state.
Returning from Standby Mode to Smart Card Interface Mode:
7. Clear the standby state.
8. Set the CKE1 bit in SCSCR1 to the value for the fixed output state at the start of standby (the
current SCK pin state).
9. Set smart card interface mode and output the clock. Clock signal generation is started with the
normal duty cycle.
Normal operation
Normal operation
Standby mode
1 2 3
4
5 6
7
8 9
Figure 17.13 Procedure for Stopping and Restarting the Clock