Section 12 Timer Unit (TMU)
SH7751 Group, SH7751R Group
Page 324 of 1128
R01UH0457EJ0301 Rev. 3.01
Sep 24, 2013
Bits 15 to 9, 7, and 6 (Channels 0 and 1); Bits 15 to 10 (Channel 2)—Reserved:
These bits are
always read as 0. A write to these bits is invalid, but the write value should always be 0.
Bit 9—Input Capture Interrupt Flag (ICPF) (Channel 2 Only):
Status flag, provided in
channel 2 only, that indicates the occurrence of input capture.
Bit 9: ICPF
Description
0
Input capture has not occurred
(Initial value)
[Clearing condition]
When 0 is written to ICPF
1
Input capture has occurred
[Setting condition]
When input capture occurs
*
Note:
*
Writing 1 does not change the value.
Bit 8—Underflow Flag (UNF):
Status flag that indicates the occurrence of underflow.
Bit 8: UNF
Description
0
TCNT has not underflowed
(Initial value)
[Clearing condition]
When 0 is written to UNF
1
TCNT has underflowed
[Setting condition]
When TCNT underflows
*
Note:
*
Writing 1 does not change the value.
Bits 7 and 6—Input Capture Control (ICPE1, ICPE0) (Channel 2 Only):
These bits, provided
in channel 2 only, specify whether the input capture function is used, and control enabling or
disabling of interrupt generation when the function is used.
When the input capture function is used, a data transfer request is sent to the DMAC in the event
of input capture.
When using the input capture function, the TCLK pin must be designated as an input pin with the
TCOE bit in the TOCR register. The CKEG bits specify whether the rising edge or falling edge of
the TCLK signal is used to set the TCNT2 value in the input capture register (TCPR2).