SH7751 Group, SH7751R Group
Section 15 Serial Communication Interface (SCI)
R01UH0457EJ0301 Rev. 3.01
Page 651 of 1128
Sep 24, 2013
Receive data full interrupt generated
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
User-defined receive start flag = 1
?
Read ORER and FER flags in SCSSR1
Read RDRF flag in SCSSR1
Read receive data in SCRDR1
Set user-defined receive start flag to 1
End of ID reception handling
End of data reception
RTE
Error handling
Read ORER and FER flags in SCSSR1
Read receive data in SCRDR1
Clear user-defined receive start flag to 0
Set RDRF = 0 and MPIE = 1
FER or ORER = 1
?
FER or ORER = 1
?
MPIE = 0
?
This station's ID
?
All data received
?
Figure 15.15 Sample Flowchart of Multiprocessor Serial Reception with Interrupt
Generation
Figure 15.16 shows a sample flowchart of multiprocessor serial reception. To perform
multiprocessor serial reception, first enable the SCI for data reception and then follow the
procedure shown below.