Section 3 Memory Management Unit (MMU)
SH7751 Group, SH7751R Group
Page 66 of 1128
R01UH0457EJ0301 Rev. 3.01
Sep 24, 2013
3.1.3
Register Configuration
The MMU registers are shown in table 3.1.
Table 3.1
MMU Registers
Name
Abbrevia-
tion
R/W
Initial
Value
*
1
P4
Address
*
2
Area 7
Address
*
2
Acces
s Size
Page table entry high
register
PTEH R/W
Undefined
H'FF00 0000 H'1F00 0000 32
Page table entry low
register
PTEL R/W
Undefined
H'FF00 0004 H'1F00 0004 32
Page table entry
assistance register
PTEA R/W
Undefined
H'FF00 0034 H'1F00 0034 32
Translation table base
register
TTB R/W
Undefined
H'FF00 0008 H'1F00 0008 32
TLB exception address
register
TEA R/W
Undefined
H'FF00 000C H'1F00 000C 32
MMU control register
MMUCR
R/W
H'0000 0000 H'FF00 0010 H'1F00
0010 32
Notes: 1. The initial value is the value after a power-on reset or manual reset.
2. P4 address is the address when using the virtual/physical address space P4 area. The
area 7 address is the address used when making an access from physical address
space area 7 using the TLB.
3.1.4
Caution
Operation is not guaranteed if an area designated as a reserved area in this manual is accessed.