Appendix B
Image Reference
Test
High contrast resolution
Method
All the 0 and 100% level stripes in all the resolution patches should be separate and
distinct.
Test
Low contrast resolution and noise
Method
All the mid-level 2 on - 2 off stripes in all the resolution patches should be visible and
distinct. This is a sensitive test for noise in the display’s video amplifiers.
Test
Quick gamma check
Method
The average brightness level of the small gamma dither box should match the brightness
of the larger surrounding box. This is a visual check to see if the display’s gamma
correction is producing the correct mid-level response.
Test
Video gain linearity and gamma
Method
The individual grayscale boxes all should be at their indicated levels. A small aperture
photometer is usually required to get accurate and repeatable readings.
Test
Contrast and brightness check
Method
On a display with properly adjusted brightness and contrast controls, both the 5% and
95% contrast boxes should be clearly visible inside their larger surrounding 0% and 100%
boxes.
Test
Video amplifier stability
Method
The two black-and-white windows should show sharp transitions between the smaller box
and the surrounding window. Streaking may be an indication of undershoot or overshoot
while ghost images may indicate a ringing problem.
Test
Excessive overscan and off-center alignment
Method
The entire border should be clearly visible on the face of the tube and not be hidden by the
edge of the glass or by any bezel.
Test
Interlace flicker
Summary of Contents for 881
Page 1: ...881 882 Video Test Instrument User Guide 882E for HDMI ...
Page 12: ...10 Contents ...
Page 50: ...38 Chapter 1 Getting Started ...
Page 84: ...72 Chapter 2 Testing Video Displays ...
Page 99: ...882 Video Test Instrument User Guide Rev A 35 87 ...
Page 102: ...90 Chapter 3 Administrative Tasks ...
Page 107: ...882 Video Test Instrument User Guide Rev A 35 95 ...
Page 216: ...204 Chapter 5 Working with Formats ...
Page 248: ...236 Chapter 7 Working with Images ...
Page 264: ...252 Chapter 8 Working with Test Sequences ...
Page 382: ...40 Chapter 11 Testing EDID for HDMI 2 Expand the EDID Block in the navigation view ...
Page 446: ...104 Chapter 12 CEC Interactive Troubleshooting Environment ITE ...
Page 493: ...882 Video Test Instrument User Guide Rev A 35 151 ...
Page 591: ...882 Video Test Instrument User Guide Rev A 35 213 Commands by name ...
Page 687: ...882 Video Test Instrument User Guide Rev A 35 309 Example DVIC 23 FMTU ...
Page 1018: ...580 Appendix B Image Reference The EMITest5 image is shown below ...
Page 1094: ...656 Appendix B Image Reference ...
Page 1124: ...686 Appendix C Error Messages ...
Page 1140: ...702 Appendix D Format Reference ...