4 Configuration and Wiring
4 - 64
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
Selection of Leakage Breaker for Servo Drive at 3 kW or less
Note These values vary greatly depending of the installation conditions of the motor power cable and the mea-
surement conditions. Use the values just as a reference.
Servo Drive
model
(R88D-)
Servomotor
model
(R88D-)
Input power
Leakage current
(3 m cable)
Increase per 10 m of
cable length
1SN01L-ECT
1M10030S
Single-phase 100 V
0.6 mA
0.3 mA
1SN02L-ECT
1M20030S
Single-phase 100 V
1SN04L-ECT
1M40030S
Single-phase 100 V
1SN01H-ECT
1M10030T
Single-phase 200 V
1.5 mA
1.3 mA
3-phase 200 V
1SN02H-ECT
1M20030T
Single-phase 200 V
3-phase 200 V
1SN04H-ECT
1M40030T
Single-phase 200 V
3-phase 200 V
1SN08H-ECT
1M75030T
Single-phase 200 V
3-phase 200 V
1SN10H-ECT
1L1K030T
3-phase 200 V
1M1K020T
3-phase 200 V
1M90010T
3-phase 200 V
1SN15H-ECT
1L1K530T
Single-phase 200 V
2.2 mA
1.9 mA
3-phase 200 V
1M1K520T
Single-phase 200 V
3-phase 200 V
1SN20H-ECT
1L2K030T
3-phase 200 V
1M2K020T
3-phase 200 V
1M2K010T
3-phase 200 V
1SN30H-ECT
1L3K030T
3-phase 200 V
1M3K020T
3-phase 200 V
1M3K010T
3-phase 200 V
1SN06F-ECT
1M40020C
3-phase 400 V
1.9 mA
1.7 mA
1M60020C
3-phase 400 V
1SN10F-ECT
1L75030C
3-phase 400 V
1L1K030C
3-phase 400 V
1M1K020C
3-phase 400 V
1M90010C
3-phase 400 V
1SN15F-ECT
1L1K530C
3-phase 400 V
1M1K520C
3-phase 400 V
1SN20F-ECT
1L2K030C
3-phase 400 V
2.4 mA
3.0 mA
1M2K020C
3-phase 400 V
1M2K010C
3-phase 400 V
1SN30F-ECT
1L3K030C
3-phase 400 V
1M3K020C
3-phase 400 V
1M3K010C
3-phase 400 V
Summary of Contents for R88D-1SN ECT Series