Obey the following conditions when installing.
• Clearance with peripheral equipment: 50 mm min.
• Wire length: 3 m max.
Use attached connectors when extending wirings. Specifications for the connectors are shown below.
• Connector model: WFR-2 (WAGO)
• Wire size: AWG16, 1.3 mm
2
• Length of stripped wire: 11±1 mm
An example of using heat-resistant polyvinyl chloride insulated wires (HIV) at the ambient temperature
of 50°C. Use wires with the rated voltage of 600 V or higher.
Length of stripped wire of external dynamic brake resistor while shipping is specified 19±1 mm. Set to
the specified length before wiring the resistor to the connectors.
Follow the specified length of stripped wire of Servo Drive side at 19±1 mm.
4-1-6
External Dynamic Brake Resistor Installation Condition