4 Configuration and Wiring
4 - 44
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
This section describes a procedure for change of cable outlet direction for connector Type M23 or M40.
The change of cable outlet directions shall be up to five times. Pre-determine the cable outlet directions
such as mounting a Servomotor to devices, etc. before the change.
1
Determine the cable outlet directions.
Refer to
on page 2-99 to fix the cable outlet direction. The connec-
tor has a dead angle. When you change the cable outlet direction, avoid excessive force applied
to the connector. Otherwise, failures of the connector may result.
2
Mount a cable and lock it firmly.
Mount a cable to a connector, referring to
4-2-3 Connector Attachment Procedure
Lock a cable securely to be fixed to a connector. If the lock is loosened, a connector is removed.
That may cause injury and failure of a connector.
3
Place your hand on the end of a connector at a cable side and apply force slowly toward mov-
able direction to change the cable outlet direction.
Apply force horizontally to movable directions. When you apply force to the end of a connector,
the force over 100 N is required. Force applied to not-specified direction may result in failure of
a connector.
4-2-4
Procedure for Change of Cable Outlet Direction for Connector
Type M23 or M40
Movable range
(Cable outlet direction can be changed)
Dead angle range
(Cable outlet direction cannot be changed)
Movable
direction
Movable
direction