![background image](http://html1.mh-extra.com/html/omron/omnuc-g5-r88d-kn-series/omnuc-g5-r88d-kn-series_user-manual_742785402.webp)
11-9
11-3 Alarms
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
11
Error and Maintenance
33
0
Interface input duplicate
allocation error 1
Detected a duplicated setting among
the interface input signals (IN1, IN2,
IN3 and IN4).
1
Interface input duplicate
allocation error 2
Detected a duplicated setting among
the interface input signals (IN5, IN6,
IN7 and IN8).
2
Interface input function
number error 1
Detected that a non-defined number was
assigned to the interface input signals
(IN1, IN2, IN3 or IN4). Alternatively, a
setting error was detected.
3
Interface input function
number error 2
Detected that a non-defined number was
assigned to the interface input signals
(IN5, IN6, IN7 or IN8). Alternatively, a
setting error was detected.
4
Interface output function
number error 1
Detected that a non-defined number
was assigned to the interface output
signal (OUTM1).
5
Interface output function
number error 2
Detected that a non-defined number
was assigned to the interface output
signal (OUTM2).
8
Latch input allocation error Detected an error on the latch input
allocation.
34
0
Overrun limit error
The motor exceeded the allowable
operating range set in the Overrun
Limit Setting (Pn514) with respect to
the position command input.
36
0 to
2
Parameter error
Data in the Parameter Save area was
corrupted when the power supply was
turned ON and data was read from the
EEPROM.
37
0 to
2
Parameters destruction
The checksum for the data read from
the EEPROM when the power supply
was turned ON does not match.
Alarm
number
Error detection function
Detection details and
probable cause
Attribute
Main Sub
History
Can be
reset
Emergency
stop *1