4-1
4-1 Installation Conditions
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
4
System Design
4-1 Installation Conditions
Servo Drive Installation Conditions
Dimension Conditions around Equipment
Install drives according to the dimensions shown in the following illustration to ensure proper heat
dispersion inside the drive and convection inside the panel. If the drives are installed side by side,
install a fan for air circulation to prevent uneven temperatures inside the panel.
Mounting Direction
Mount the drives in a direction (perpendicular) so that the model number can be seen properly.
Environment Operating Conditions
The environment in which drives are operated must meet the following conditions. Drives may
malfunction if operated under any other conditions.
Operating ambient temperature: 0 to
55
C (Take into account temperature rises in the
following individual drives themselves.)
Operating humidity: 90% RH max. (with no condensation)
Operating atmosphere: No corrosive gases.
Altitude: 1,000 m max.
Drives of 100-V or 200-V with the capacity of 750 W max. can be installed side by side with a 1-
mm clearance (W in above illustration). However, the specifications for operating ambient
temperature differs by the drives.
Drive A
: 0 to 50
C
Drive B
: 0 to 40
C
Drive C
: 0 to 45
C
W
W
Side
A
B
C
Drive
Drive
Drive
40 mm or more
100 mm or more
Air
Air
Fan
Fan
W = 10 mm or more
100 mm or more