8-1
8-1 Basic Parameters
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
8
Parameters Details
8-1 Basic Parameters
Some parameters are enabled when the power is turned ON after it is turned OFF. They are
indicated in the table below. Ensure you turn off the power, confirm that the power indicator goes
off, and turn on the power again, after you change the settings of these parameters.
Do not change the parameters that are indicated as Reserved for manufacturer use, or Reserved
for the system. Also, do not change the set values that are indicted as Unused or Reserved for
the system.
See below for the data attributes.
It switches the motor rotation direction for a position, speed or torque command.
Explanation of Set Values
Regarding the motor rotation direction, when seen from load-side axis, clockwise is referred to as
CW and counterclockwise as CCW.
Set the CONTROL mode to be used.
Explanation of Set Values
A
: Always enabled
B
: Prohibited to change during motor rotation or commanding.
If it is changed during motor rotation or commanding, the reflection timing is
unknown.
C
: Enabled after a power reset, or after the CONFIG command is executed via
MECHATROLINK-II communications.
R
: Enabled after a power reset.
It is not enabled by the CONFIG command via MECHATROLINK-II
communications.
Pn000
Rotation Direction Switching
Setting
range
0 to 1
Unit
Default
setting
1
Data
attribute
C
All
Set
value
Description
0
Forward direction command sets the motor rotation direction to CW.
1
Forward direction command sets the motor rotation direction to CCW.
CW
CCW
Pn001
CONTROL mode Selection
Setting
range
0 to 6
Unit
Default
setting
0
Data
attribute
R
All
Set value
Description
0 to 5
Switch control
6
Full closing control