4-43
4-4 Regenerative Energy Absorption
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
4
System Design
Regenerative Energy Absorption with an External Regeneration Resistor
If the regenerative energy exceeds the regeneration absorption capacity of the drive, connect
an External Regeneration Resistor.
Connect the External Regeneration Resistor between B1 and B2 terminals on the drive.
Double-check the terminal names when connecting the resistor because the drive may be
damaged if connected to the wrong terminals.
The External Regeneration Resistor will heat up to approx. 120
C. Do not place it near
equipment and wiring that is easily affected by heat. Attach radiator plates suitable for the heat
radiation conditions.
External Regeneration Resistor
Characteristics
Model
Resistance
value
Nominal
capacity
The amount of
regeneration
absorption for 120
C
temperature rise
Heat
radiation
condition
Thermal switch output
specifications
R88A-
RR08050S
50
80 W
20 W
Aluminum
250
250,
Thickness: 3.0
Operating temperature
150
C
5% NC contact
Rated output: 30 VDC,
50 mA max.
R88A-
RR080100S
100
80 W
20 W
Aluminum
250
250,
Thickness: 3.0
Operating temperature
150
C
5% NC contact
Rated output: 30 VDC,
50 mA max.
R88A-
RR22047S
47
220 W
70 W
Aluminum
350
350,
Thickness: 3.0
Operating temperature:
170
7
C
NC contact
Rated output: 250 VAC,
0.2 A max.
R88A-
RR50020S
20
500 W
180 W
Aluminum
600
600,
Thickness: 3.0
Operating temperature
200
7
C
NC contact
Rated output: 250 VAC,
0.2 A max.
24 VDC, 0.2 A max.