8-31
8-5 Interface Monitor Setting Parameters
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
8
Parameters Details
8-5 Interface Monitor Setting Parameters
Set the function and logic for the general-purpose input 1 (IN1).
Refer to the Details of Control Inputs in "3-1 Servo Drive Specifications (P.3-1)", as well as "6-1
Set the function and logic for the general-purpose input 2 (IN2).
Refer to the Details of Control Inputs in "3-1 Servo Drive Specifications (P.3-1)", as well as "6-1
Set the function and logic for the general-purpose input 3 (IN3).
Refer to the Details of Control Inputs in "3-1 Servo Drive Specifications (P.3-1)", as well as "6-1
Set the function and logic for the general-purpose input 4 (IN4).
Refer to the Details of Control Inputs in "3-1 Servo Drive Specifications (P.3-1)", as well as "6-1
Set the function and logic for the general-purpose input 5 (IN5).
Refer to the Details of Control Inputs in "3-1 Servo Drive Specifications (P.3-1)", as well as "6-1
Set the function and logic for the general-purpose input 6 (IN6).
Refer to the Details of Control Inputs in "3-1 Servo Drive Specifications (P.3-1)", as well as "6-1
Set the function and logic for the general-purpose input 7 (IN7).
Refer to the Details of Control Inputs in "3-1 Servo Drive Specifications (P.3-1)", as well as "6-1
Pn400
Input Signal Selection 1
Setting range
0 to 00FFFFFFh
Unit
Default setting
00949494h
Data attribute
C
All
Pn401
Input Signal Selection 2
Setting range
0 to 00FFFFFFh
Unit
Default setting
00818181h
Data attribute
C
All
Pn402
Input Signal Selection 3
Setting range
0 to 00FFFFFFh
Unit
Default setting
00828282h
Data attribute
C
All
Pn403
Input Signal Selection 4
Setting range
0 to 00FFFFFFh
Unit
Default setting
00222222h
Data attribute
C
All
Pn404
Input Signal Selection 5
Setting range
0 to 00FFFFFFh
Unit
Default setting 002B2B2Bh Data attribute
C
All
Pn405
Input Signal Selection 6
Setting range
0 to 00FFFFFFh
Unit
Default setting
00212121h
Data attribute
C
All
Pn406
Input Signal Selection 7
Setting range
0 to 00FFFFFFh
Unit
Default setting
00202020h
Data attribute
C
All