Specifications
2,000-r/min motor (400 VAC)
The following graphs show the characteristics with a 3-m standard cable and a 400-VAC input.
• R88M-K40020F/C (400 W)
• R88M-K60020F/C (600 W)
• R88M-K1K020F/C (1 kW)
• R88M-K1K520F/C (1.5 kW)
• R88M-K2K020F/C (2 kW)
• R88M-K3K0F/C (3 kW)
• R88M-K4K020F/C (4 kW)
• R88M-K5K020F/C (5 kW)
Use the following Servomotors in the ranges shown in the graphs below. Using outside of
these ranges may cause the motor to generate heat, which could result in encoder malfunction.
• R88M-K5K020H/T/F/C (5 kW)
0
1000
2000
3
6 5.73
1.91
1.91
5.73 (2700)
3000 (r/min)
3.5
(2400)
2.0
1.3
Power supply voltage
dropped by 10%
Continuous operation range
Momentary operation range
(N • m)
0
1000
2000
5
10 8.59
2.86
2.86
8.59 (2400)
3000 (r/min)
4.5
(2100)
1.9
Power supply voltage
dropped by 10%
Continuous operation range
Momentary operation range
(N • m)
0
1000
2000
5
10
15 14.3
4.77
4.77
14.3 (2200)
3000 (r/min)
6.0
4.0
3.2
(2000)
Power supply voltage
dropped by 10%
Continuous operation range
Momentary operation range
(N • m)
10
0
20
21.5
7.16
7.16
21.5 (2300)
1000
2000
3000 (r/min)
10.0
6.0
4.8
(2000)
Power supply voltage
dropped by 10%
Continuous operation range
Momentary operation range
(N • m)
15
0
30 28.6
9.55
9.55
28.6 (2200)
1000
2000
3000 (r/min)
15.0
11.0
6.4
(2000)
Power supply voltage
dropped by 10%
Continuous operation range
Momentary operation range
(N • m)
25
0
50 43.0
14.3
14.3
43.0 (2400)
1000
2000
3000 (r/min)
28.0
20.0
9.5
(2200)
Power supply voltage
dropped by 10%
Continuous operation range
Momentary operation range
(N • m)
25
0
50
57.3
19.1
19.1
57.3 (2100)
1000
2000
3000 (r/min)
25.0
13.0
(1900)
Power supply voltage
dropped by 10%
Continuous operation range
Momentary operation range
(N • m)
35
0
70
71.6
23.9
23.9
71.6 (2100)
1000
2000
3000 (r/min)
20.0
3.0
(1900)
Power supply voltage
dropped by 10%
Continuous operation range
Momentary operation range
(N • m)
Rated torque ratio [%]
Ambient
temperature
[
°
C]
100%
85%
90%
10
0
20
30
40
Without brake
With brake