![background image](http://html1.mh-extra.com/html/omron/omnuc-g5-r88d-kn-series/omnuc-g5-r88d-kn-series_user-manual_742785265.webp)
6
6-36
6-10 Gain Switching 3 Function
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
Applied Functions
6-10 Gain Switching 3 Function
The function adds a new setting to the gain switching function of the GAIN SWITCHING INPUT
OPERATING mode Selection (Pn114). It switches the gain right before a stop.
The positioning time can be reduced by keeping the gain immediately before the stop at a
higher level for a certain period of time.
Operating Conditions
You can use the gain 3 switching function in the following situations for position control or full
closing control.
Parameters Requiring Settings
Conditions
Operating mode POSITION CONTROL mode, SPEED CONTROL mode
Others
• Servo-ON state.
• The factors other than control parameters are set correctly.
• This includes the torque limit. The motor operates normally without any failures.
Parameter
number
Parameter name
Explanation
Reference
Pn605
Gain 3 Effective Time
Set effective time of gain 3.
Pn606
Gain 3 Ratio Setting
Set gain 3 as a multiple of gain 1.