background image

Quick Start Installation Guide

 

807118 v1.00 01.21 G5 BC Quick Start Guide

1

Zip  

HydroTap G5

Q

uick Start Installation Guide

Command Centre 
Boiling/Chilled models

AFFIX PRODUCT LABEL HERE

Visit our website to 

download the manuals

Australia

UK

Summary of Contents for HydroTap G5 Touch-Free Wave

Page 1: ...tion Guide 807118 v1 00 01 21 G5 BC Quick Start Guide 1 Zip HydroTap G5 Quick Start Installation Guide Command Centre Boiling Chilled models AFFIX PRODUCT LABEL HERE Visit our website to download the...

Page 2: ...WARNINGS AND REGULATORY INSTRUCTIONS 6 SECTION 4 Technical data 8 SECTION 5 Supplied parts checklist 10 SECTION 6 Set up the ventilation 11 SECTION 7 Connect the water supply 14 SECTION 8 Set the bypa...

Page 3: ...d operating your HydroTap download read the Command Centre installation and user instructions which can be found online at Australia www zipwater com UK specify zipwater co uk Read and use the instruc...

Page 4: ...enance of the refrigeration unit must be carried out by an accredited service provider or qualified refrigeration technician Keep ventilation openings in the appliance enclosure or in the built in str...

Page 5: ...Do not lift the Command Centre by the front cover or any of its connections Airflow The Zip HydroTap operates within the ambient temperature range 5 C 35 C Proper air circulation must be provided The...

Page 6: ...ver of the appliance under any circumstances without first isolating the appliance from the power supply Connect only to a potable wholesome cat1 mains water supply Never locate the system near or cle...

Page 7: ...ower supplies at the rear of the appliance For safe operation the HydroTap is designed to be installed commissioned and used within 48 hours Should the HydroTap not be required for an extended period...

Page 8: ...x 470 x 333 30 BC60 BC60 H 2 1 450 500 x 470 x 333 30 BC40 BC40 H 1 97 450 500 x 470 x 333 30 BC30 BC30 H 1 9 2 2 280 x 470 x 333 23 BC20 BC20 H 1 9 280 x 470 x 333 23 BC Home 1 44 280 x 470 x 333 30...

Page 9: ...o reduce the maximum mains regulated pressure 700kPa in Australia protecting the system against pressure surges above 500kPa Water supply connection 1 2 BSP G1 2 Booster specification Specification Ra...

Page 10: ...s Optional Optional Separate Mains mixer Tap instructions Optional Optional Command Centre Command Centre Mains electrical supply cable Water supply inlet hose Water supply inlet adaptor and strainer...

Page 11: ...tilation Command Centre width A clearance envelope around all Command Centres must be provided to allow ventilation for the safe and effective use of the HydroTap system 200mm 50mm 50mm Use instructio...

Page 12: ...rigerant gas in the unlikely event of a leak Vent tray dimensions WxDxH mm 500 x 515 555 x 40 Cold air is drawn in through the inlet vent and gap provided by the door buffers Inlet vent is mounted ove...

Page 13: ...ion is required Contact your Zip service provider for options including additional vents and fan kit All models Cold air is drawn in through the inlet vent and lower gap provided by the door buffers I...

Page 14: ...lied Connect together Connect to Command Centre see pages 19 20 Connect to Command Centre see pages 19 20 Note Mixer tap installations also use a Tee piece as part of the water supply plumbing connect...

Page 15: ...e limescale filter Water in Bypass out see pages 19 20 Water out Bypass in see pages 19 20 Insert Remove Insert Remove For filter head and scale filter installation use the guide supplied with the fil...

Page 16: ...118 v1 00 01 21 G5 BC Quick Start Guide SECTION 9 Fit the Booster a b c d e f 10 15 Note Take care not to break the clips when removing or installing the Booster Supplied with selected models or avail...

Page 17: ...anner while tightening hoses 3 8 BSP connections Do not connect to electrical power until commissioning Do not over tighten hose connections Braided hoses supplied cannot be lengthened Strainer Cold w...

Page 18: ...ble Do not connect to the mains socket until commissioning Installation diagrams are for illustrative purposes only Hoses are not shown to scale and cannot be lengthened Tips for hose connection Push...

Page 19: ...B res comm USB check USB position NG T BYPASS IN VENT BYPASS OUT USB MAINS IN CHILLED OUTLET ARKLING OUTLET MAINS IN hich way round arkling Booster Mains Water Lime scale Filter BC40 BC60 BC100 model...

Page 20: ...NG OUT BYPASS IN VENT BYPASS OUT B res comm USB MAINS IN C 175 comm USB CHILLED OUTLET chec posi USB MAINS IN MAINS IN Mains Water BC20 BC30 BC Home models Zip Vented Mixer Tap connections if supplied...

Page 21: ...fresh water through the tank s 3 times as shown by the cycle counter s The tank s will fill automatically but when prompted use the tap to dispense and empty Dispense water from the hot tank using th...

Page 22: ...22 Quick Start Installation Guide 807118 v1 00 01 21 G5 BC Quick Start Guide Notes...

Page 23: ...Quick Start Installation Guide 807118 v1 00 01 21 G5 BC Quick Start Guide 23 Notes...

Page 24: ...sGreen Dereham Norfolk NR191JG 03456005005 sales zipindustries co uk specify zipwater co uk WMKA00099 AS 3498 Refer to User Guide for operation and maintenance ZipWater Australia PtyLtd ABN4600057872...